Product Identification

Product ID:PSI-690A PRIMER
MSDS Date:06/04/1991
FSC:8010
NIIN:00N058808
MSDS Number: BXFLP

Responsible Party
POLYMERIC SYSTEMS INC
WHEATLAND AND MASON STS
PHOENIXVILLE, PA 19460
US

Emergency Phone: 215-935-1170

Info Phone: 215-935-1170

Preparer: E.F. CLUFF

Cage: 0KND3

Contractor
POLYMERIC SYSTEMS, INC.
PHOENIXVILLE, PA 19460 US

Telephone: 610-935-1170

Cage: 0KND3

Ingredients

METHYL ISOBUTYL CARBINOL

CAS: 108-11-2

RTECS: SA7350000

Fraction By Weight: 93%

OSHA PEL 25 PPM, S

ACGIH TLV: 25 PPM;40 STEL, S


ETHYL POLYSILICATE

CAS: 68412-37-3

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: N/K


POLY(BUTYLTITANATE); (BUTYL POLYTITANATE)

CAS: 9022-96-2

Fraction By Weight: 1%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM, C, S


6.5 LBS/GAL (780 G/L).

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRITATION & ANESTHESIA.
IRRITATION OF EYES, SKIN & UPPER RESPIRATORY TRACT. CHRONIC:NONE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:EYE, SKIN & RESPIRATORY DISORDERS
MAY BE AGGRAVATED BY EXPOSURE TO THIS PRODUCT.

First Aid

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:WASH W/SOAP
& WATER. INHAL:REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING
DIFFICULT. INGEST:WASH OUT MOUTH W/WATER. CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:106F,41C
Lower Limits:1%
Upper Limits:5.5%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER, ALCOHOL FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPOR MAY TRAVEL CONSIDERABLE DISTANCE TO
IGNITION SOURCE & FLASH BACK.

Accidental Release

Spill Release Procedures:TAKE UP W/ABSORBENT MATERIAL. STORE IN
APPROPRIATE CONTAINER. AVOID PROLONGED INHALATION OF VAPOR OR
CONTACT W/LIQUID. WASH RESIDUES W/LARGE AMOUNTS OF WATER.
Neutralizing Agent:WATER.

Handling

Handling and Storage Precautions:AVOID IGNITION SOURCES: FLAME, SPARKS,
EXTREME HEAT.
Other Precautions:KEEP CONTAINERS TIGHTLY CLOSED.

Exposure Controls

Respiratory Protection:IF LARGE AMOUNTS ARE USED IN A POORLY VENTILATED
SPACE, USE A NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE RESPIRATOR
W/ORGANIC VAPOR CARTRIDGES TO PROTECT AGAINST METHYL ISOBUTYL
CARBINOL VAPORS.
Ventilation:LOCAL EXHAUST MAY BE REQUIRED IN CLOSED SPACES. RECOMMEND
10 CHANGES PER HOUR.
Protective Gloves:DISPOSABLE PLASTIC GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:270F,132C
Melt/Freeze Pt:M.P/F.P Text:-130F,-90C
Vapor Pres:3.7 @ 20C
Vapor Density:3.5
Spec Gravity:0.8 (H*2O=1)
pH:7
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:98%
Appearance and Odor:COLORLESS LIQUID; PLEASANT, SWEET ODOR.
Percent Volatiles by Volume:96

Stability

Stability Indicator/Materials to Avoid:YES
ACID CHLORIDES & OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAMES, SPARKS & EXTREME HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SILICA & TITANIA FROM COMBUSTION.

Disposal

Waste Disposal Methods:INCINERATE I/A/W LOCAL, STATE & FEDERAL
REGULATIONS. MATERIAL MAY BE INCINERATED W/CARE TAKEN TO PREVENT
ENVIRONMENTAL CONTAMINATION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their